- AC5000F series 40kW-180kW chilled water room level precision air conditioners
AC5000F series 40kW-180kW chilled water room level precision air conditioners adopt modular and integral structural solutions, compact structure, easy handling, full front maintenance, and effectively save the room area; The full series cooling capacity ranges from 40kW to 180kW, to provide more flexible configuration requirements.
.png)
.png)
.png)
- 
 Safe and reliable Safe and reliableUse water as a refrigerant, close to nature, green, healthy, environmental protection; The use of high-performance EC centrifugal fan, high efficiency, small volume, low noise, high reliability, long life; With high reliability, the unit average time without failure MTBF≥ One hundred thousand hours. 
- 
 Energy efficient Energy efficientUnit energy efficiency ratio (COP) up to 20 or more, to ensure that the equipment room and other places to achieve low PUE operation; The power distribution of the equipment is small, which can save the overall electrical investment, reduce the energy consumption of the unit, and low system operating costs and maintenance costs. 
- 
 Intelligent control Intelligent controlAdopt intelligent controller for PID adjustment, temperature control accuracy can reach ± 0.5℃, humidity control accuracy can reach ± 5%, to create a more stable operating environment for the equipment room; And standard RS485 communication interface; The electric valve with large flow coefficient is used to accurately adjust the water flow, reduce the water resistance, save energy consumption, and ensure stable water supply. 
- Application scenario
.jpg) 
 - Data Center
- Such as supercomputing center, data center, cloud computing center
 
.jpg) 
 - Medium and large switching room
 
.jpg) 
 - Mobile room, computer room and electronic information Department
 
 
 
- Technical specification
| Model | AC5000F-40 Series | AC5000F-70 Series | AC5000F-100 Series | AC5000F-130 Series | AC5000F-160 Series | AC5000F-180 Series | 
| Function | Optional constant temperature and humidity function | |||||
| Main Power supply | 380V/3Ph/50Hz | |||||
| Inlet water Temperature (℃) | 15℃ | |||||
| Outlet Temperature (℃) | 21℃ | |||||
| Return-air condition | 35℃/30% | |||||
| Total cooling capacity (kW) | 42.6 | 72.0 | 100.3 | 132.9 | 165.5 | 189.2 | 
| Cooling capacity (kw) | 42.6 | 72.0 | 100.3 | 132.9 | 165.5 | 189.2 | 
| Water flow (m³ /h) | 6.1 | 10.3 | 14.7 | 19.8 | 23.7 | 27.1 | 
| Water side resistance (kPa) | 40.0 | 59.2 | 55.0 | 58.0 | 75.0 | 78.0 | 
| Single cooling full load power (kW) | 3.5 | 3.5 | 7.0 | 7.0 | 10.5 | 10.5 | 
| Single cooling full load current (A) | 5.3 | 5.3 | 10 | 11.8 | 16.0 | 16.4 | 
| Circulating Air Volume (CMH) | 9000 | 14800 | 24000 | 28400 | 38000 | 38500 | 
| Number of fans | 1 | 1 | 2 | 2 | 3 | 3 | 
| Size: L * D * H (mm) | 925*1000*1980 | 1820*1000*1980 | 2530*1000*1980 | |||
Note: The above parameters are based on the ambient condition of 35℃/ 30%RH for return air. This technical parameter is only for selection reference, the actual parameter is subject to the software selection result.