- Single cabinet CR4000-LC series
CR4000-LC series liquid cooled cloud cabinet is a new generation of data center cabinet, liquid cooled cabinet has the characteristics of high efficiency, energy saving and environmental protection. Compared with the traditional air-cooled cooling method, the liquid-cooled cabinet has higher cooling efficiency and lower energy consumption. The core components of the CR4000-LC series of liquid cooled cloud cabinets include components such as cold plates, pumps and heat exchangers. The cold plates interact with the heat source and equipment to remove heat from the equipment through liquid circulation. The pump circulates the liquid through the system, ensuring constant heat transfer. Heat exchangers discharge the heat absorbed by the liquid to the external environment to keep the temperature of the system stable, so the liquid-cooled cabinet is the best choice for the new generation of data centers.
-
Efficient cooling
Liquid cooling systems have high heat conductivity and can achieve efficient heat transfer in a small space, thereby improving the cooling efficiency of the data center.
-
Improve performance
Due to increased cooling efficiency, equipment in data centers can operate at lower temperatures, thereby improving their performance and stability.
-
Life extension
The liquid-cooled cabinet can effectively reduce the temperature of the device and reduce the risk of device damage due to overheating, thus extending the service life of the device.
-
Energy saving and environmental protection
Compared with the traditional air-cooled cooling method, the liquid-cooled cabinet does not use a lot of electricity to drive the fan, so it has lower energy consumption and less carbon emissions.
- Application scenario
- Headquarters
- Large Branch
- Bank
- Government
- Operator
- Education
- Medical
- Power


- Technical specification
Name | Specifications |
Centralized management | Single cabinet power environment monitoring and server monitoring |
Display | 13.3-inch touch screen (1400mm optional) |
Maximum power supply | 3*39.6kW (no redundancy), 3x36kW(3 redundant modules) |
Power module efficiency | 96% |
Rack CDU cooling capacity | 100kW |
Inlet water temperature | 20℃~45℃ |
System cooling | Cold plate liquid cooling + backplane evaporative cooling (optional) |
Cabinet dimensions: W x D x H (mm) | 600*1200/1400*2200 |
Cabinet bearing | > 3100kg |
Input voltage | AC380/DC240V |
Input routes | Two AC or one AC+ one DC |
Input AC voltage range | 180 Vac to 264 Vac |
Input frequency range | 45Hz to 65Hz |
Input DC voltage range | 180Vdc to 320Vdc |
Output rated voltage | DC54V |
Operating temperature | 5℃~40℃ |
Working humidity | 8% ~ 90% |
Working altitude | ≤ 3050m |