Modular Channel Data Center -CR8000

CR8000 micro-module data center is a new generation of efficient and energy-saving data center. It adopts the All-In-One design concept, integrated design ideas, and extremely simplified deployment mode. It integrates cabinet system, power supply and distribution system, refrigeration system, monitoring system, etc., to meet the deployment requirements of various medium and large integrated delivery rooms. Component standardization, prefabrication, and modular deployment effectively reduce the communication cost of customers, save delivery time, and save time, labor, and worry for customers.

  • Safe and reliable

    The key components of the system are designed with N+1 or 2N to ensure the stable operation of the equipment to the maximum extent. Supports the intelligent linkage between skylights and fire control, and automatically opens the skylights 0.5 seconds after receiving the fire signal to let the fire extinguishing gas enter.

  • Efficient

    High efficiency modular UPS, the overall efficiency of more than 95%. Closed cold and hot channel isolation design, avoid gas mixed flow, ensure refrigeration efficiency. The near-end row cooling reduces the cooling loss, and the overall PUE of the smart module is less than 1.5.

  • Intelligence

    The close end self-closing channel two-motion sliding door is standard with anti-clamp function. The UPS supports intelligent sleep and automatically invokes power modules based on load. The row air conditioner uses a variable frequency compressor and an EC fan to automatically adjust the air volume.

Application scenario

  • Large, Medium, and Small data center scenarios
Mainly applies to scenarios of small and medium-sized data centers.
    Technical specification
    Overall characteristics
    Channel specification Single row: LX2200-2400X2000-2200, L≤ 15m;
    Double row: LX3200-3600X2000-2200, L≤ 15m;
    Cabinet depth support 1100mm, 1200mm; Cabinet height supports 2000mm, 2200mm;
    Aisle widths support 1200mm and 1800mm
    Total counter number Single row: 25 counters; Double row: 50 counters
    Installation method Raised floor installation, can also be installed directly on the cement floor
    Power system 380/400/415Vac, 50/60Hz, 3Ph+N+PE
    Power supply and distribution system
    UPS input voltage 380/400/415Vac, 50/60Hz, 3Ph+N+PE
    UPS rated capacity 20-600kVA
    UPS configuration mode N, N+1, 2N
    UPS input power factor ≥ 0.99 < / td >
    UPS Output Power factor 1
    Maintenance mode Online Hot swap maintenance
    IT Cabinet Power supply mode Mains/oil + mains/oil; UPS+UPS; UPS+ Mains/Oil unit
    Refrigeration system
    Air Conditioner selection Row air cooled/chilled water, room air cooled/chilled water
    Cooling mode Air-cooled, chilled water
    Air conditioner installation Indoor unit raised floor installation, outdoor unit flat cement installation
    Fan type EC Fan
    Air supply mode Row level: horizontal air supply; Room level: up/down air supply
    Air conditioner indoor unit size See Selection table
    Monitoring Management system
    Function module Environmental monitoring module, power monitoring module, management monitoring module (optional)
    Access method Remote web access, local touch screen (external: 43-inch large screen; Built-in: other sizes), mobile app(optional)
    Alarm mode Local sound and light alarm, SMS alarm, email alarm, telephone alarm, wechat alarm
    Cabinet system
    Size: Width * Depth * Height (mm) 600/800X1100/1200X2000/2200
    Free space 42U/47U
    Authentication status Static load, dynamic load, seismic