- Modular Channel Data Center -CR8000
CR8000 micro-module data center is a new generation of efficient and energy-saving data center. It adopts the All-In-One design concept, integrated design ideas, and extremely simplified deployment mode. It integrates cabinet system, power supply and distribution system, refrigeration system, monitoring system, etc., to meet the deployment requirements of various medium and large integrated delivery rooms. Component standardization, prefabrication, and modular deployment effectively reduce the communication cost of customers, save delivery time, and save time, labor, and worry for customers.
-
Safe and reliable
The key components of the system are designed with N+1 or 2N to ensure the stable operation of the equipment to the maximum extent. Supports the intelligent linkage between skylights and fire control, and automatically opens the skylights 0.5 seconds after receiving the fire signal to let the fire extinguishing gas enter.
-
Efficient
High efficiency modular UPS, the overall efficiency of more than 95%. Closed cold and hot channel isolation design, avoid gas mixed flow, ensure refrigeration efficiency. The near-end row cooling reduces the cooling loss, and the overall PUE of the smart module is less than 1.5.
-
Intelligence
The close end self-closing channel two-motion sliding door is standard with anti-clamp function. The UPS supports intelligent sleep and automatically invokes power modules based on load. The row air conditioner uses a variable frequency compressor and an EC fan to automatically adjust the air volume.
- Application scenario
- Technical specification
Overall characteristics | |
Channel specification | Single row: LX2200-2400X2000-2200, L≤ 15m; Double row: LX3200-3600X2000-2200, L≤ 15m; Cabinet depth support 1100mm, 1200mm; Cabinet height supports 2000mm, 2200mm; Aisle widths support 1200mm and 1800mm |
Total counter number | Single row: 25 counters; Double row: 50 counters |
Installation method | Raised floor installation, can also be installed directly on the cement floor |
Power system | 380/400/415Vac, 50/60Hz, 3Ph+N+PE |
Power supply and distribution system | |
UPS input voltage | 380/400/415Vac, 50/60Hz, 3Ph+N+PE |
UPS rated capacity | 20-600kVA |
UPS configuration mode | N, N+1, 2N |
UPS input power factor | ≥ 0.99 < / td > |
UPS Output Power factor | 1 |
Maintenance mode | Online Hot swap maintenance |
IT Cabinet Power supply mode | Mains/oil + mains/oil; UPS+UPS; UPS+ Mains/Oil unit |
Refrigeration system | |
Air Conditioner selection | Row air cooled/chilled water, room air cooled/chilled water |
Cooling mode | Air-cooled, chilled water |
Air conditioner installation | Indoor unit raised floor installation, outdoor unit flat cement installation |
Fan type | EC Fan |
Air supply mode | Row level: horizontal air supply; Room level: up/down air supply |
Air conditioner indoor unit size | See Selection table |
Monitoring Management system | |
Function module | Environmental monitoring module, power monitoring module, management monitoring module (optional) |
Access method | Remote web access, local touch screen (external: 43-inch large screen; Built-in: other sizes), mobile app(optional) |
Alarm mode | Local sound and light alarm, SMS alarm, email alarm, telephone alarm, wechat alarm |
Cabinet system | |
Size: Width * Depth * Height (mm) | 600/800X1100/1200X2000/2200 |
Free space | 42U/47U |
Authentication status | Static load, dynamic load, seismic |